Home / Water Learning Center / What a Heritage actually removes, stage by stage
Our systems

What a Heritage actually removes, stage by stage

A Heritage is three stages, each solving a different physics problem. One works by size, one by chemistry, one by pressure across a membrane. Together they handle organisms, sediment, chlorine and chloramine, solvents, pesticides, PFAS, microplastics — and at the kitchen tap, the dissolved metals nothing else catches.

A Heritage suite installed on a utility room wall: a tall stainless ultrafiltration vessel with a black Aquamor cap, two white carbon cartridge housings beside it, pressure gauges above, and polished copper pipework running in and out through isolation valves.
A Heritage as installed. The stainless column on the left holds the ultrafiltration membrane — the stage that removes. The two white housings are the carbon cartridges — the stage that reduces. The gauges above them are how the system tells you when to change the flush.

A Heritage is three stages, and each one is solving a different physics problem. One works by size, one works by chemistry, and one works by pressure across a membrane so fine that dissolved salts cannot follow the water through it.

Put together they handle a remarkably wide range of what can be in household water — microorganisms, sediment, chlorine and chloramine, industrial and agricultural chemicals, PFAS, microplastics, and at the kitchen tap the dissolved metals that nothing else catches. What follows is what each stage does, how the three hand off to each other, and the one maintenance decision you actually control.

Stage one: the ultrafiltration membrane

At the top of a Heritage is a four-inch by forty-inch stainless vessel holding an ultrafiltration membrane — a dense bundle of hollow fibers with a nominal pore size of 0.015 micron. It sits where the main enters the house, so everything downstream of it is already treated.

It works by size, and nothing else. Water passes through the fiber walls under household pressure. Anything bigger than the pore does not go with it. There is no chemistry, nothing is adsorbed, and no media is consumed — which is why this stage is cleanable rather than replaceable, and why it holds its performance instead of drifting toward a change-out date.

What the membrane takes out:

  • Microorganisms — bacteria including E. coli, protozoa, cysts, and most viruses.
  • Suspended solids and turbidity — fine dirt, silt, mud, cloudiness and suspended particles.
  • Macromolecules and organics — proteins, endotoxins, natural organic material and some high-molecular-weight organic compounds.
  • Debris — microplastics and algae.

The scale of it is easier to feel with a number attached. A Cryptosporidium oocyst measures roughly 4.8 to 5.6 micrometres and a Giardia cyst 8 to 19. Against a 0.015 micron pore, a Cryptosporidium oocyst is on the order of three hundred times too large to pass and a Giardia cyst closer to eight hundred times. Bacteria, at half a micron to two microns, are still thirty to a hundred and thirty times too big.

STOPPED BY THE MEMBRANE 0.015 µm pore Most viruses Bacteria Cryptosporidium Giardia Sediment, algae dissolved minerals pass → 0.01 0.1 1 10 100 micrometres, logarithmic scale — each step is ten times the one before
Everything to the right of the pore line is too large to pass. The dissolved minerals and metals to the left of it are what stages two and three are for.

The cyst performance is the part that carries independent certification: the membrane is certified to NSF/ANSI 53, tested against a challenge of more than 50,000 cysts per millilitre, and it achieved 99.99% average reduction. Cysts matter because the shell shrugs off chlorine at the doses a utility can legally use, which is why they sit behind a disproportionate share of documented waterborne outbreaks. Chemistry does not beat them. A pore smaller than they are does.

The membrane also protects everything behind it. Sediment, turbidity and colloidal material are intercepted here, so the carbon downstream never spends its capacity filtering dirt — it spends all of it on the chemistry it is actually good at.

One note for completeness, because it is on the manufacturer's own documentation: the system is not classified as a microbiological purifier. That is a specific EPA protocol for equipment intended to make unsafe water safe to drink, and it is a different thing from what this stage does on treated municipal supply. It is a stage that takes microorganisms out of water the utility has already disinfected — not a substitute for a boil notice.

Stage two: the carbon blocks

Behind the membrane sit two powdered carbon block cartridges, and this is the stage most people underestimate. A carbon block works two ways at once — chemical adsorption, where contaminant molecules bind to an enormous internal surface area, and mechanical filtration, because the powder is pressed into a solid block the water has to pass through rather than dosed loose the way a treatment plant does it.

What the carbon takes out:

  • Disinfectants and their byproducts — chlorine, chloramines, and trihalomethanes.
  • Organic chemicals and pollutants — volatile organic compounds, industrial solvents, fuels, pharmaceuticals and synthetic organic chemicals.
  • Pesticides and herbicides — agricultural runoff chemicals and weed killers, which matter more in this part of Oklahoma than most people assume.
  • Heavy metals — lead, mercury and copper, depending on the density and rating of the block.
  • Fine particulates and microplastics — sediment, rust, turbidity and microplastics down to sub-micron levels.
  • Biological cysts — Giardia and Cryptosporidium, in finer sub-micron block configurations.
  • Aesthetic impurities — bad tastes, musty odours and sulphur compounds.

On a Heritage specifically, the figure the manufacturer publishes is 99.95% chlorine reduction at every tap, shower and appliance in the house, and the cartridges carry NSF/ANSI 42 and CSA B483.1 certification for chlorine, taste and odour.

Chloramine, and why there are two cartridges

Worth knowing if you live here: Tulsa uses chloramine rather than free chlorine, and so do eleven of the fourteen metro systems. Carbon handles chloramine — the chemistry ends with nitrogen gas and chloride, the same harmless destination — but it is more stubborn than free chlorine and needs longer contact with more carbon to get there. The trade literature puts it at two to four times the contact time.

Which is exactly why a Heritage runs two cartridges in the post-filter manifold rather than one. At any given flow the water spends twice as long against carbon as a single-cartridge system allows. The configuration is a direct answer to the water this metro actually has. We wrote about chloramine at more length in a separate piece.

PFAS

Powdered carbon is one of the genuinely effective tools against PFAS, and the mechanism is worth understanding rather than taking on faith. PFAS molecules adsorb onto the vast internal surface area and microscopic pore structure of the carbon. The very fine particle size means they bind quickly, through a combination of Van der Waals forces, hydrophobic interaction and electrostatic attraction. Because the powder is formed into a solid block the water must travel through, every drop is forced into contact with that surface rather than flowing past it.

Scale control

The cartridges also carry food-grade polyphosphate, which holds calcium and magnesium in solution so the crystals cannot nucleate and bond to the inside of a pipe, a heating element or a fixture. It is the difference between a water heater element that stays clean and one that crusts over.

It is worth being precise about what this is, because the industry is often not. Sequestration is not softening. The minerals leave your tap still dissolved in the water, and a hardness test will read the same before and after — what changes is that the scale does not form. If what you want is the hardness number itself to come down, ion exchange is the technology that does it, with the salt, drain and regeneration cycle that comes with it. We laid out both options here.

Stage three: the Wellspring, at the kitchen tap

Lead, arsenic and fluoride are dissolved in water. They are not particles, so no filter with a pore size can catch them, and they do not adhere reliably enough to be a whole-home carbon claim. They need a different mechanism entirely — and this is the stage that supplies it.

Reverse osmosis pushes water through a membrane fine enough that the water molecules pass and the dissolved contaminants are left behind and flushed away. Certified to NSF/ANSI 58, held by the manufacturer, Nimbus Water Systems, for reduction of:

  • Lead
  • Arsenic (pentavalent)
  • Fluoride
  • Total dissolved solids
  • Cysts

A Wellspring is included with every Heritage, at no extra cost. It treats one tap — the water you drink and cook with, which is the water those contaminants actually matter in. And because it sits behind the whole-home stages, arriving water that has already had its chlorine, sediment and organics removed, its cartridge lasts about twice as long as the same unit would on its own.

Some water goes to the drain. That is not waste in the sense people assume — it is the mechanism. The reject stream is how the membrane carries the concentrated contaminants away instead of accumulating them.

How the three stages hand off

The design logic is simple once you see it laid out. Stage one removes what has size — organisms, sediment, organics, microplastics. Stage two removes what has chemistry — disinfectants, solvents, pesticides, PFAS, tastes and odours, and it controls scale on the way through. Stage three removes what is dissolved — the metals and ions nothing upstream can catch — at the one tap where that matters most.

Each stage also makes the next one work better. The membrane keeps dirt off the carbon so the carbon spends its life on chemistry. The carbon keeps chlorine off the RO membrane, which chlorine would otherwise damage, and doubles the life of its cartridge. Nothing in the chain is doing a job it is poorly suited to, which is the whole reason it is three stages instead of one very optimistic one.

The flush, and when to change it

Here is the part owners actually operate, and the part almost nobody is told about.

The ultrafiltration membrane is cleanable rather than consumable. What keeps it that way is the self-clean flush: a motorised valve reverses water across the fibers and carries the caught material out to drain. From the factory it runs once an hour for fifteen seconds, the duration is programmable between five and sixty seconds, and the schedule is set at the controller. You can trigger one by hand at the panel any time.

That flush is why the published membrane life reads "up to five years, source-water dependent" rather than a fixed replacement date. The phrase source-water dependent is an invitation to pay attention.

The gauges are the instrument, not the calendar

A Heritage has pressure gauges at the ultrafiltration outlet and at the post-filter stage. The number that matters is the difference between them, tracked over time at a consistent flow. A gradual rise in that difference is the long-established first indicator that a membrane is holding onto more than its flush is carrying away, and it shows up well before anything is noticeable at a tap.

So the most valuable five minutes of the whole ownership of this system happen in the first week. Open one bathtub tap wide, let it settle, and write both gauge readings and the date on a piece of tape stuck to the wall beside the unit. That is your baseline. Every later judgement is a comparison against it.

What changes the load

Heavy rain. Tulsa draws from Oologah, Spavinaw, Eucha and Hudson; Broken Arrow treats Verdigris River water. Storm runoff moves sediment into source water, and a wet stretch is the clearest case for shortening the interval for a few weeks.

Late summer. Warm water grows algae, and algal organic matter compacts into a membrane surface rather than rinsing off easily. If you shorten the interval once a year by default, this is when.

Winter, and a trap worth knowing. Cold water is around half again as viscous as summer tap water, so the same membrane passes less at the same pressure. That can look exactly like fouling on a gauge. It is physics, and it reverses in spring. Compare winter to last winter, not to last July.

Main breaks and street work. A city main repair pushes a slug of disturbed sediment down the line all at once. One manual flush after the notice goes out beats a month of schedule changes.

A house that has sat empty. Vacation, a second home, a rental between tenants. Standing water is organic-load territory — the same reason the health agencies tell you to flush your own taps after time away. Run a manual flush before you start using the house again.

The rule, in one line

Shorten the interval when the pressure differential is climbing faster than it used to. Lengthen it when a full season passes with the differential flat. The hourly default is a sensible average, and plenty of homes never need to touch it. But your water comes from a specific plant, through specific pipes, in a specific season. The controller is adjustable because the water is variable, and the gauge on the wall is how the system tells you which way to move it.

Eventually a membrane does reach the end of its service life, and that is anticipated rather than surprising — it is what the five-year figure describes. When it arrives it is a part change, not a system replacement: the stainless vessel, the controller, the motorised valve, the manifold and the cartridge housings all stay exactly where they are. A cartridge system reaches a replacement date on a calendar whether your water earned it or not. This one tells you when.

The short version

Stage one, the UF membrane: bacteria, protozoa, cysts, most viruses, suspended solids and turbidity, proteins and endotoxins, natural organic material, microplastics and algae. Cyst reduction independently certified to NSF/ANSI 53 at 99.99% average.

Stage two, the carbon blocks: chlorine at 99.95%, chloramine, trihalomethanes, VOCs, solvents, fuels, pharmaceuticals, pesticides and herbicides, heavy metals, PFAS, microplastics, tastes and odours — plus polyphosphate scale control. Certified to NSF/ANSI 42 and CSA B483.1 for chlorine, taste and odour.

Stage three, the Wellspring RO: lead, arsenic, fluoride, total dissolved solids and cysts, at the kitchen tap. Certified to NSF/ANSI 58. Included with every Heritage.

That is a wide range of water chemistry for one wall of a utility room, and the reason it works is that no single stage is being asked to do a job it is wrong for. If you want to know which of it your own water actually calls for, the honest way to find out is to measure it — which is what the walkthrough is for, and it costs nothing.

Sources

  1. CDC DPDx — Giardiasis (cyst dimensions)
  2. Kansas State University — Cryptosporidium oocyst measurements
  3. Water Conditioning & Purification — Chlorine and chloramine removal by activated carbon
  4. Water Conditioning & Purification — Standards for POU/POE activated carbon systems (NSF/ANSI 42 and 53)
  5. Lenntech — Ultrafiltration operation and troubleshooting
  6. City of Tulsa — Annual Water Quality Report

Every figure in this article comes from the published sources listed above. This is general information, not advice about the water at any particular address.

More from the Learning Center

Have we been to your sink?

Tell people what actually happened — what we tested, what we told you, whether it helped. Thirty seconds, and it is the main way our neighbors find us.