Residential Systems Drinking Water Commercial Replacement Filters Water Walkthrough Water Learning Center User guides Service & repair Which size fits my home? Contact us Why Sevade Call (918) 359-5921
Home / Water Learning Center / Your backyard pool is a 20,000-gallon emergency …
Preparedness

Your backyard pool is a 20,000-gallon emergency water supply

A typical residential pool holds 15,000 to 25,000 gallons, and a careful family of four uses about 200 a day. That is 60 to 90 days of water sitting behind the house — if you have the pump, the filtration and the power to reach it. Here is the whole setup, sized and costed, with a printable checklist.

A lit backyard swimming pool at dusk on a hillside above a city skyline, with a row of white chemical carboys stacked on the stone deck in the foreground and a covered porch glowing behind.
Fifteen to twenty-five thousand gallons, already filtered and already chlorinated. The gap between that and a working tap is a pump, a few hoses, and a power plan.

If you have a backyard pool, you already own the biggest emergency water reserve in your neighborhood. A typical residential pool holds 15,000 to 25,000 gallons. A family of four living carefully uses about 200 gallons a day for drinking, cooking, bathing, and flushing. Allow for summer evaporation and the murky last couple of feet you will not want to pump, and that is still 60 to 90 days of water sitting behind your house right now.

Most homeowners never think of it that way, and most never need to. But if a storm, a main break, or a grid failure ever takes the municipal supply offline for more than a day or two, the household that can turn pool water into tap water keeps showering, flushing, and cooking while everyone else is lining up for bottled water.

The good news is that the equipment to do this is ordinary, affordable, and mostly off-the-shelf. This post walks through what you need, how to size it, and the two main ways to power it, including what changes if you already have a Generac standby generator on the side of your house.

Two things turn pool water into house water

Pool water is clear, filtered, and chlorinated, but it is not drinking water as it sits. It carries fine sediment, chlorine and its byproducts, dissolved salts and stabilizer, sunscreen, body oils, and whatever the wind blew in. Two pieces of equipment bridge the gap.

A whole-home filtration system. The water has to pass through real treatment before it reaches your taps: sediment removal, ultrafiltration to reduce bacteria and cysts, carbon to reduce chlorine and organics, and reverse osmosis at the kitchen sink for the water you drink and cook with. A system rated for surface or non-municipal source water handles this. Check your system's spec sheet for its source-water rating and its maximum inlet chlorine before you count on it.

Be clear-eyed about what each stage does. Ultrafiltration (0.01 to 0.1 micron) reduces bacteria, Giardia, and Cryptosporidium, which matters because Crypto survives normal pool chlorine levels. Carbon reduces chlorine, chloramines, and the organics that sunscreen and swimmers leave behind, and it must sit ahead of the RO membrane, which chlorine destroys. Neither stage removes anything dissolved: salts, sodium, cyanuric acid, or metals. Only reverse osmosis does that, and only on the drinking-water line.

That makes two things non-negotiable. Everything you drink or cook with comes from the RO tap, not the shower or the bathroom sink. And before you rely on the system, test the pool and then test the RO tap with a $20 TDS meter and a strip kit for free chlorine, cyanuric acid, and pH so you know what you are starting with.

A pump that delivers real pressure. Your filtration system has a minimum inlet pressure it needs to flow properly. For a whole-home unit that is typically around 50 psi to deliver 15 gallons per minute, enough to run a shower and a sink at the same time. Gravity and a pool pump will not get you there. You need a pump built to lift water out of the pool and push it into the house at municipal pressure.

Everything else in this post is about choosing and powering that pump.

Saltwater pool or chlorine pool? It matters more than you think

A saltwater pool is still a chlorine pool. The salt cell makes chlorine from dissolved salt by electrolysis, so the sanitizer is the same. The water is not. A saltwater pool runs 4,000 to 6,000 ppm total dissolved solids, with sodium around 1,200 to 1,800 ppm and chloride around 2,000 to 2,800 ppm. A conventional chlorine pool runs 1,000 to 2,500 ppm TDS. Neither is drinking water as it sits; the EPA's secondary standard for TDS is 500 ppm.

Chlorine pool (tabs or liquid)Saltwater pool (salt cell)
Total dissolved solids1,000 to 2,500 ppm4,000 to 6,000 ppm
Sodium100 to 500 ppm1,200 to 1,800 ppm
Chloride200 to 800 ppm2,000 to 2,800 ppm
Cyanuric acid30 to 100+ ppm60 to 80 ppm, often higher
Chlorate (electrolysis byproduct)LowElevated
After UF + carbon, for showers and flushingClear, dechlorinated, moderately hardClear, dechlorinated, tastes like diluted seawater
Drinking water through RO at 50 psiWorks normallyOutput collapses without a booster pump

That last row is the practical difference. A reverse osmosis membrane has to push against the osmotic pressure of the water it is treating, roughly 1 psi for every 100 ppm of TDS. A chlorine pool at 1,500 ppm costs the membrane about 15 psi, leaving plenty of driving pressure. A saltwater pool at 4,500 ppm costs 45 psi. Feed that at the 50 psi a house runs on and the RO has 5 psi to work with: production drops to a trickle and the water that does come through is not as clean. Saltwater pool owners need a small booster pump on the RO feed (80 to 100 psi), or should plan on filling drinking containers slowly over the day.

Saltwater also attacks equipment. Chloride at these levels corrodes copper and stainless over time, and fast at 2,000 ppm. Flush the pump, hoses, and fittings with fresh water after every use period, expect to replace the water heater's anode rod afterward, and flush the house plumbing thoroughly when city water returns. A conventional chlorine pool is kinder to everything it touches.

One more dissolved chemical neither pool type is free of: cyanuric acid, the stabilizer in chlorine tabs and dichlor shock. It builds up for years because nothing but draining removes it, and ultrafiltration and carbon pass it straight through. Only RO takes it out. There is no federal drinking-water limit for it, and it is not acutely toxic, but it is one more reason the RO tap is the only drinking tap during an emergency.

Choosing the pump

The right tool is a 1½ HP shallow-well jet pump. The Goulds J15S is the benchmark, and any 1½ HP equivalent from Red Lion, Pentair, or Myers with a published performance table works the same way. Read the table, not the box: the "max GPM" on the carton is measured at zero pressure and tells you nothing about what the pump does at 50 psi.

Why 1½ HP and not something smaller or cheaper:

PumpFlow at 50 psi, 5 ft liftFlow at 50 psi, 15 ft liftVerdict
1 HP jet pump (Goulds J10S)16.6 GPM13.8 GPMRight on the edge; any extra hose or a dirty strainer puts you under
1½ HP jet pump (Goulds J15S)25.0 GPM20.4 GPMComfortable margin, still 15.6 GPM at 60 psi
Plug-in booster pumps (Grundfos SCALA2 class)Under 10 GPMNot rated for liftBuilt to boost pressure that already exists, not to lift from a pool

A few things the pump should have: 115/230 V dual-voltage motor so it runs on a standard 120 V circuit now and can be rewired for 240 V later, a built-in pressure switch, cast iron or stainless construction, and a continuous-duty rating. The J15S checks every box and runs roughly $900 to $1,850 depending on the retailer, so shop around.

One setup choice matters more than brand. The pressure switch on these pumps is preset to 30/50 psi, which means the pump shuts off at 50 and restarts at 30. For a filtration system that wants 50 psi, change that to a 40/60 switch so the inlet never dips below 40 while water is running.

For an emergency rig, you can also skip the pressure switch entirely and run the pump manually: switch it on for a filling window, use water, switch it off. That is the simplest and lowest-energy way to run it. If other family members will use water without thinking about the pump, add a 20-gallon pressure tank (Amtrol WX-202 or Water Worker HT-20B) so it behaves like a normal house.

Hoses, fittings, and the one connection you must get right

The pump dictates the hose sizes: 1¼″ on the suction side, 1″ on the discharge side. Do not neck either one down to garden hose. At 15 GPM, a 50-foot garden hose eats about 35 psi in friction alone; a 1″ hose loses 3 to 4 psi over the same run.

Pool to pump (suction side, 1¼″)

  • 1¼″ reinforced PVC suction hose with a rigid spiral helix, in the shortest length that reaches. Soft hose collapses under suction.
  • 1¼″ foot valve with strainer on the pool end, zip-tied inside a skimmer-net bag and hung 18 to 24 inches below the surface.
  • Two stainless clamps on every barb. Air leaks on this side are the number one reason jet pumps lose prime.
  • Set the pump at pool-deck level, close to the water. Every foot of lift costs flow.

Pump to filtration inlet (discharge side, 1″)

  • 1″ brass check valve and a 0-100 psi gauge at the pump outlet.
  • 1″ potable-rated hose (NSF-61, 100+ psi working pressure), or permanent 1″ PEX if you want a plug-and-go setup.
  • A 1″ spin-down sediment prefilter right before the filtration system to catch grit and protect the fine stages.
  • Cam-lock fittings at both ends make the whole thing a five-minute connection.

Isolate the house from the city main, properly. Pool water is a non-potable source, and plumbing code treats connecting one to a home that is also tied to the public main as a high-hazard cross-connection. Closing the main shutoff is not enough, and a simple dual-check valve is not rated for it. The connection needs a reduced-pressure-zone (RPZ) backflow assembly installed and tested by a licensed plumber, or a true physical air gap. Many utilities also require notification or a permit for any auxiliary water source, so call yours. This is a half-day job for a plumber, and the right time to do it is now, not during an outage.

When city water returns, flush every line in the house and drain and refill the water heater. Pool water leaves dissolved solids behind that you do not want sitting in copper pipe or on the heater's anode rod.

Power Route A: battery power station, solar, and a portable generator

This is the route for homeowners who do not have a standby generator, or who want a system that runs quietly and sips fuel. The pieces are a large battery power station, solar panels, and a portable inverter generator held in reserve.

The power station does the daily work. A unit in the 5 kWh class, such as the Jackery Explorer 5000 Plus (7,200 W continuous, 14,400 W surge), starts and runs a 1½ HP pump with room to spare. Plug the pump into the station's 30 A outlet, not a 20 A receptacle, because the motor draws about 70 amps for a fraction of a second at every start.

The pump is a small load over a day. At 200 gallons of household use it runs about 15 minutes and uses roughly half a kilowatt-hour. One full charge on a 5 kWh station covers 8 to 10 days of water, and the station is silent while it does it.

Solar makes the fuel last. A pair of 500 W folding panels, or four to six ordinary residential panels wired to the station's high-voltage input, produce 3 to 5 kWh on a sunny Oklahoma day. That is several times what the pump needs, with the balance available for a refrigerator and lights. With solar in the mix, the generator becomes a cloudy-week backup rather than a daily chore.

The generator covers the gaps and the failures. Choose one that can do two jobs: recharge the power station with clean inverter power, and start the pump directly if the station ever fails. That rules out small 2,000 to 3,500 inverter units, which run the pump fine but trip on its starting surge. The Honda EU7000iS (5,500 W rated, 52 dB at quarter load, about a gallon of gas per full station recharge) is the quiet, efficient choice. The Predator 9500 does the same work for less than half the price at the cost of noise and a shorter track record.

Run the generator only to recharge the station, in one daytime block, and let the station run the pump. One gallon of gas buys about a week and a half of water.

Power Route B: you already have a Generac standby generator

If a Generac (or Kohler, Briggs, or Cummins) standby unit is already mounted beside your house, most of the power problem is solved. A 10 kW or larger air-cooled standby generator starts a 1½ HP motor without noticing, and the automatic transfer switch means the pump circuit is live within seconds of an outage. Here is what changes in the setup.

Put the pump on a backed-up circuit. Have your electrician add a dedicated 20 A, 120 V circuit (12 AWG) from the generator-backed panel to a weatherproof GFCI outlet near where the pump will sit. If your transfer switch only covers selected circuits rather than the whole panel, confirm the new one is on the backed-up side. Wiring the pump for 240 V on a 15 A two-pole breaker is even better: it halves the motor current and makes the easiest possible start.

Decide how the pump turns on. With a standby generator, the hands-off setup is the pressure switch (40/60) plus a 20-gallon pressure tank, exactly as if the pump were a well pump. The house works normally and nobody has to think about it.

A battery power station is optional but still worth considering. Standby generators run the whole time the grid is down, whether or not anything is drawing power, and an air-cooled unit burns fuel at idle. If your plan includes running the generator only part of the day to stretch propane, a mid-size power station on the pump circuit keeps water available during the quiet hours.

Know your fuel. A natural-gas unit has effectively unlimited runtime as long as the gas utility stays up, which it usually does through storms and grid failures but not always through earthquakes or major infrastructure events. A propane unit on a 500-gallon tank gives roughly a week of continuous running for a 20 kW class generator at half load; stretching that to 90 days means running it a few hours a day, not around the clock. Check your tank gauge and your delivery contract now, while delivery trucks are still running.

Curious how your own tap compares? Book a free water walkthrough and we will test the water at your sink.

Route A vs. Route B at a glance

Neither route is wrong. Route A is quieter and sips fuel; Route B is hands-off and already paid for if you own the generator.

Route A: power station + solar + portable generatorRoute B: existing Generac standby
Starts the pumpYes, from the power station (silent) or the generatorYes, easily
Hands-off operationManual or pressure-switch; someone manages chargingFully automatic with transfer switch
NoiseNear silent day to day; 52 dB when the Honda runs60 to 70 dB whenever the grid is down and the unit is running
Fuel over 90 daysNear zero with solar; about 10 gal gas without itNatural gas: utility-dependent; propane: tank-limited unless run part-time
Setup cost if starting from scratch$6,000 to $9,000 (station, panels, Honda-class generator)$500 to $1,000 (new circuit, pressure tank) on top of the generator you own
PortabilityYes; the same gear serves a camper or a second propertyFixed to the house
Single point of failureNone; three independent ways to make waterThe generator itself, unless paired with a power station
Best forHomeowners without a standby unit; anyone prioritizing low profile and fuel independenceHomeowners who already own a standby unit and want it to just work

Keep the pool alive while you use it

Here is the part most emergency plans miss: if the power is out, your pool pump is out too. Without circulation and without anyone adding chlorine, free chlorine in a sunlit pool falls to zero within one to three days. After that the pool is a warm, nutrient-rich pond. Algae blooms in five to ten days in summer, bacteria follow the algae, and mosquitoes arrive within a couple of weeks.

What neglect costs you. A green pool is still a water source, but it turns a two-stage filtration job into a four-stage one, and the stages you lean on hardest are the ones that wear out.

  • Sediment load explodes. Dead algae, dust, and leaf debris that circulation would have caught now get stirred up when you pump. Your spin-down prefilter needs flushing daily instead of weekly, and the ultrafiltration stage fouls fast: flow drops and you are swapping membranes you cannot easily replace mid-emergency.
  • Organics overwhelm the carbon. Carbon has a finite capacity. Algae and its byproducts, including the earthy taste-and-odor compounds that make pond water smell like dirt, eat into that capacity, so the stage protecting your RO membrane runs out sooner.
  • Pathogen risk rises. Chlorine was handling most bacteria. Without it, ultrafiltration is the only barrier left, and you have gone from two independent barriers to one.
  • Recovery makes it worse. Once a pool is green, the only fix is a heavy shock of 10 to 30 ppm chlorine. That spike exhausts carbon rapidly, and if it breaks through to the RO membrane it ruins it. Neglect forces you into the one treatment you least want while drawing water.

A maintained pool gives clear water and filter stages that last the whole outage. A neglected one gives a week of easy water, then a scramble: cloudy water, falling flow, consumables running out, and a pool that needs 20 to 30 pounds of shock to bring back. Fifteen minutes a day with a brush and a chlorine floater is cheap insurance.

Treat the pool as a reservoir you are maintaining, not a swimming pool you are ignoring.

  • Keep chlorine in the water by hand. A floating dispenser with 3-inch tabs or a daily dose of liquid chlorine holds 1 to 3 ppm free chlorine. Test every other day with strips.
  • Brush the walls and floor every few days so algae cannot get a foothold, and skim debris before it sinks and rots.
  • Keep the cover on when you are not drawing water. It slows evaporation, keeps leaves out, and protects the chlorine from sunlight.
  • If you can spare the power, run the pool pump for 15 to 30 minutes a day. If you cannot, the hand maintenance above is enough to keep the water clear for weeks.
  • Use chlorine and pH adjusters only. Skip algaecides (most are copper-based, and copper has a 1.3 ppm drinking-water action level), clarifiers, phosphate removers, and metal sequestrants. Every one of them adds chemistry your filtration system then has to deal with.
  • Avoid shocking the pool to 10 ppm or more while you are drawing from it. High chlorine exhausts your carbon stage quickly and, if it gets past the carbon, damages the RO membrane.

Planning for a long one: fuel, noise, and habits

A weekend outage is easy. The planning that pays off is for the scenario where fuel deliveries stop and the lights stay off for weeks. Three habits make either route last.

Treat the pump as a scheduled appliance. Fill the pressure tank or run a water window twice a day rather than letting the switch cycle dozens of times. Fewer starts, less energy, and the pump never runs at 2 a.m.

Run engines in short daytime blocks. Whether it is a portable recharging a power station or a standby unit on a part-time schedule, one three-hour run at midday uses less fuel and draws less attention than several short sessions. Ambient noise is highest in daylight and so is your solar output.

Store fuel for the plan you actually have. For Route A, 10 gallons of ethanol-free gasoline with stabilizer, rotated into your vehicles twice a year, is a 90-day reserve once solar is doing the daily work. For a propane Generac, know your tank level and what a part-time schedule does to it. For natural gas, know where your meter shutoff is and what your utility has said about outage resilience.

Flush and reset afterward. When the outage ends, run fresh water through the pump and hoses before storing them, flush every line in the house, drain and refill the water heater, and replace filter stages that saw pool water for more than a few weeks. Then test the tap once more before you call it done.

Where to buy everything

Every item below is a stock product you can order today. Prices are what we saw at the time of writing and move around; the links go to each maker or seller, where you can look up the model for photos and spec sheets. Local Tractor Supply, Home Depot, and plumbing-supply counters carry most of the plumbing items off the shelf.

The pump and water side

ItemModelApprox. priceWhere
1½ HP shallow-well jet pumpGoulds J15S (115/230 V)$900 to $1,850SupplyHouse · Pool360 · any Goulds dealer
Pump performance tableGoulds JS+ technical brochureFreeGoulds Water Technology
20-gal pressure tank, valueWater Worker HT-20B$200 to $210Home Depot
20-gal pressure tank, premiumAmtrol Well-X-Trol WX-202$320 to $400SupplyHouse · Home Depot
1¼″ PVC suction hose with helixKanaflex 112 series, Abbott Rubber, Hydromaxx$2 to $3 per footQuality Farm Supply · Tractor Supply and Home Depot by the foot
1¼″ brass foot valve with strainerCampbell FV-5TLF or Water Source TFV-125NL$35 to $40Zoro · Tractor Supply
1″ spin-down sediment prefilterRusco 1-100-F (100 mesh)$60 to $90SupplyHouse
1″ potable discharge hoseAny NSF-61 rated, 100+ psi (Apache, Kuriyama, RV/marine white hose)$3 to $6 per footPlumbing supply, Grainger, McMaster-Carr, RV dealers
40/60 pressure switchSquare D Pumptrol FSG2J24$25 to $35Any hardware store
Brass check valve, gauge, cam-locks, clamps1″ and 1¼″$80 to $120 totalHardware or plumbing supply

The power side

ItemModelApprox. priceWhere
Battery power stationJackery Explorer 5000 Plus (5,040 Wh, 7,200 W)$3,150 to $3,500Jackery
Folding solar panelsJackery SolarSaga 500X (pair)Sold as a bundle with the stationOff Grid Stores
Residential panels (alternative)Four to six 400 W panels wired in series to the high-voltage input$500 to $900Local solar installers, surplus and used markets
Generator, quietest and most fuel-efficientHonda EU7000iS (5,500 W rated, 52 dB)$4,400 to $5,000Honda Power Equipment dealers
Generator, valuePredator 9500 inverter (7,600 W rated)$1,900 to $2,300Harbor Freight
Generator, dual fuelChampion 201175 8500 W dual-fuel inverter$1,400 to $2,100Champion Power Equipment
Fuel stabilizerSta-Bil or PRI-G$10 to $25Any auto parts store

If you already have a Generac standby unit, your power-side list shrinks to one line: an electrician's visit to add the pump circuit, typically $300 to $600.

The checklist

Do these on a calm Saturday and the hard part is finished.

Pool-to-tap readiness checklist

Twelve items. Print it, put it on the wall by the pump, and work down the list.

  1. Confirm your whole-home filtration system is rated for surface or non-municipal source water, note its maximum inlet chlorine, and make sure the drinking line has RO
  2. Buy a 1½ HP shallow-well jet pump with a 115/230 V motor and a 40/60 pressure switch
  3. Buy 1¼″ suction hose, foot valve with strainer, 1″ potable discharge hose, check valve, gauge, and spin-down prefilter
  4. Have a licensed plumber install the pool-water inlet with a ball valve and a tested RPZ backflow assembly, and notify your water utility
  5. Route A: power station, solar panels, and a generator that can both recharge the station and start the pump on its own
  6. Route B: dedicated 20 A (or 240 V) pump circuit on the generator-backed panel, plus a 20-gallon pressure tank
  7. Run the whole system once, pool to tap, and time how long a fill takes
  8. Buy a TDS meter and test strips for free chlorine, cyanuric acid, and pH; test the pool and the RO tap during the trial run
  9. Saltwater pool: add a booster pump on the RO feed and plan to flush the pump and plumbing after use
  10. Stock chlorine tabs or liquid chlorine and a floating dispenser to keep the pool sanitized by hand during an outage
  11. Store fuel for your route and put a calendar reminder on rotating it
  12. Label the shutoffs, the connections, and the sequence on a laminated card next to the pump
Download the printable checklist (PDF)

One page, formatted for letter paper, with room to write the dates you did each one.

The pool was never just for swimming. With a pump, a few hoses, and a power plan, it is the reason your household stays comfortable while the rest of the street waits for the water to come back on.

This article is provided for general informational purposes only and does not constitute professional engineering, plumbing, electrical, or public-health advice. Pool water is not a potable water source, and treating it for household use carries risks that depend on your pool's chemistry, your equipment, and your local codes. Product names, prices, and specifications are included for reference and may change without notice; Sevade does not endorse any third-party product and receives no compensation for the links above. Before installing or operating any of the equipment described here, consult a licensed plumber and electrician, confirm requirements with your local building department and water utility, and test your water. Sevade accepts no liability for injury, property damage, or illness resulting from the use of this information.

Sources

  1. Goulds Water Technology — JS+ Series shallow well jet pumps (J5S–J15S performance ratings from the series brochure)
  2. U.S. EPA — Secondary Drinking Water Standards (TDS, chloride, copper and other aesthetic limits)
  3. U.S. EPA — Lead and Copper Rule (1.3 mg/L copper action level)
  4. U.S. CDC — Cryptosporidium fact sheet (survives in properly chlorinated pools)
  5. Jackery — Explorer 5000 Plus specifications
  6. Honda Power Equipment — EU7000iS specifications
  7. Amtrol — Well-X-Trol WX-202 pressure tank
Book a free water walkthrough

Every figure in this article comes from the published sources listed above. This is general information, not advice about the water at any particular address.

More from the Learning Center

Have we been to your sink?

Tell people what actually happened — what we tested, what we told you, whether it helped. Thirty seconds, and it is the main way our neighbors find us.